Known Issues

  • In ASCET V6 based interactive models, EHANDBOOK-NAVIGATOR does not show "Start" and "History" states for state machines.

  • When "Invisible view" info is applied to a state, EHANDBOOK-NAVIGATOR does not show the transition attached to the state.

  • Formulas text is not selectable/searchable.

  • Combination of styled and normal text are not searchable in Local Search. Example: Search strings containing bold and normal text does not yield search results.

  • EHANDBOOK-NAVIGATOR will hang if connection to INCA is not cleared properly.

    • In such a case, follow the procedure for disconnecting from INCA as indicated in the User Guide document.

  • When EHANDBOOK-NAVIGATOR is connected to INCA prior to version 7.2 SP8 and a map is modified in the experiment, the values are not updated and old values are shown.

    • Alternatively, SP 9 onwards resolves the issue.

  • Highlighting of connected elements for larger number of ports requires more RAM and time.

  • EHANDBOOK-NAVIGATOR shows a different icon for group tables in comparison to ASCET.

  • Interaction with topics having large textual content might take more time (eg. ’Find in Current Tab’).

  • Variable icon is shown in label popup for "Service" type labels .

  • Signal flow highlighting is not propagated properly for "Self Class" block in collapsed state.

    • Trigger signal flow highlighting with "Self Class" block in expanded state.

  • When using Find in EHANDBOOK File(s) with term containing punctuation characters, scrolling and highlighting of search hit is not done. Ex: <LabelName.Number> (Ex: Opm.3)

    • Use local search post topic opening or open search hits found for parameter/variable type.

  • When label amendment for hierarchies is performed, the following issue may occur: Ex: Open interactive model might not get directed to the appropriate level in interactive model in some cases.

    • Alternatively, switch to auto layout.

  • Rendering for some interactive blocks across different versions of Simulink might have a different representation. (Ex: The EHANDBOOK Container is generated using different versions of MATLAB).

  • Setting windows system scaling factor to greater than 100% might result in blurry text and images in textual documentation.

    • Alternatively, switch windows system scaling factor to 100% for all monitors.

  • When a text occurs multiple times in the same state model, Find in EHANDBOOK File(s) highlights all of them in a search hit.

  • Sometimes Navigate in action does not bring blocks to the focus area.

    • Alternatively, click Fit to View from the status toolbar to bring them to focus.

  • Usage of unsupported Simulink toolboxes might result in corrupted interactive models.

  • Usage of web fonts in EHANDBOOK container configured via commonltr.css file is not supported for EHANDBOOK Containers generated using versions older than 8.3.

  • Modification to an INCA experiment by adding or removing a variable especially an indexed variable in read-only mode requires a reconnect to make the change visible.

  • In Simulink, Inport blocks can be duplicated to so-called InportShadow blocks. InportShadow blocks are not yet fully supported in EHANDBOOK. For example, the inner label (typically a number) is missing. Furthermore, no virtual connections are established, and highlighting dependencies is not supported.

  • When adjusting the size or switching editors in EHANDBOOK-NAVIGATOR, viewers can temporarily go black.

  • When EHANDBOOK-NAVIGATOR is connected to INCA for live measurement, there could be a significant performance degradation leading to unresponsive UI.

  • In an ASCET-DEVELOPER based interactive model, the State behavior text could overflow from the State block.

  • A screenshot based on ASCET-DEVELOPER state machine could get clipped if transitions of the state machine extend outside the state or region.

  • Auto-correction of duplicate groups, functions, measurements, and characteristics for A2L files with include statements is not supported.

  • Simulink models having Pixel Icon Units may not be rendered properly.

  • Dangling virtual connections might be visible in the interactive model in case of a minimized application window.

    • Alternatively, performing some navigation or re-layouting operations would fix the interactive model.

  • Visualization of Map graph in Label pop-ups might not work on a Windows 11-Virtual machine environment.

  • In an ASCET V6 based interactive model, some Junction points may not be rendered in EHANDBOOK-NAVIGATOR. This does not have any impact on the semantics of the depicted model.

  • Self-loop connections in interactive models may sometimes overlap on other parts of the model.

  • For attachments, some icons in the Document Explorer might have a black background.

  • Expand icons in interactive models may not be clickable in default layout when other blocks/labels overlap.

    • Alternatively, blocks can be expanded using the context menu.

  • Model Explorer and Model Navigation Bar may show entries without labels when blocks do not have a name in the source model.

  • Focus may sometimes toggle between the label popup window and the main EHANDBOOK-NAVIGATOR window.

    • Alternatively, click on some part of the main EHANDBOOK-NAVIGATOR window.

  • When opening multiple model editors showing very large models EHANDBOOK-NAVIGATOR could stop working properly due to memory consumption.

    • Closing tabs can restore the application.

  • Subsystems which only contain static documentation text might be displayed wrongly.

    • In case the subsystem appears empty switch from auto layout to default layout.

  • Open model link might open the wrong location in case there are multiple blocks with the same name.

  • In case of Duplicate functions in the container, Bookmarking model will always open first function in the container and also bookmarks all function with same URI.